“Tailor-made solutions for each individual Gas installation”

High-pressure piston GAS compressors, suitable for NITROGEN (N2), Helium (He) & Argon (Ar) applications; Compact or Silent,
3+4-staged, air cooled, oil lubricated,
with Zero Loss drain system.

“Tailor-made solutions for each individual Gas installation”

High-pressure piston GAS compressors, suitable for NITROGEN (N2), Helium (He) & Argon (Ar) applications; Compact or Silent,
3+4-staged, air cooled, oil lubricated,
with Zero Loss drain system.

GAS COMPRESSORS Models

Icon label Icon label

Technical Data

Icon label Icon label

Technical Data

Icon label Icon label
Gas
Gas

Technical Data

Icon label Icon label
Gas
Gas

Technical Data

Design Specifications

Standard Equipment


  • Inlet Solenoid valve
  • Inlet Pressure regulator
  • 2 x Inlet pressure safety valves
  • Inlet Pressure Manometer
  • Inlet Pulsation chamber
  • Inlet Safety Pressure Switch
  • Inlet Vacuum Safety
  • Pressure Switch
  • Oversized Stainless Steel
  • Intercoolers & Aftercooler in all stages for optimum cooling
  • Advanced Design Cylinder Heads for optimum heat discharge
  • Safety Valves in all stages
  • Interstage and Final stage Condensate Separators
  • Final Gas Purification Filter, including coalescing prefilter (0.5 mg/m3 oil residual) and 2x large AC/MS cartridges
  • Large fan for high efficiency cooling of cylinders, intercoolers & aftercoolers, making the compressor capable for continuous operation
  • Secondary fan with independent electric motor for extra cooling (available only for Cyclone Silent model)
  • Zero Loss Automatic Condensate Drain system via condensate return piping system, back inside compressor’s crankcase
    Star/Delta starter system
    24V secondary voltage providing safety during routine operation

Optional Equipment


  • Main Switch
  • Emergency Stop button
  • Advanced digital controller (available only for Typhoon Silent and Cyclone
    Silent models)
  • Automatic Start/Stop system at the desirable pressure
  • Interstage pressure control with pressure sensors in all stages (available only for Typhoon Silent and Cyclone Silent models)
  • High temperature alarm & shutdown error
  • Oil pump lubrication (Optional)
  • Low Oil level sensor alarm & shutdown error
  • Hourmeter
  • Motor thermal overload protection
  • Voltage failure and Phase Rotation Safety device
  • Interstage and Final Stage Manometers
  • Built-In Vibration Pads
  • Non return valve before the outlet
  • Automatic belt tensioning system
  • Soundproof insulation (available only for TyphoonSilent and Cyclone Silent models)
gas_compressors

Inlet Solenoid valve

Inlet Pressure regulator

2 x Inlet pressure safety valves

Inlet Pressure Manometer

Inlet Pulsation chamber

Inlet Safety Pressure Switch

Inlet Vacuum Safety Pressure Switch

Oversized Stainless Steel Intercoolers & Aftercooler in all stages for optimum cooling

Advanced Design Cylinder Heads for optimum heat discharge

Safety Valves in all stages

Interstage and Final stage Condensate Separators

Final Gas Purification Filter, including coalescing prefilter (0.5 mg/m3 oil residual) and 2x large AC/MS cartridges

Large fan for high efficiency cooling of cylinders, intercoolers & aftercoolers, making the compressor capable for continuous operation

Secondary fan with independent electric motor for extra cooling (available only for Cyclone Silent model)

Zero Loss Automatic Condensate Drain system via condensate return piping system, back inside compressor’s crankcase

Star/Delta starter system

24V secondary voltage providing safety during routine operation

Main Switch

Emergency Stop button

Advanced digital controller (available only for Typhoon Silent and Cyclone
Silent models)

Automatic Start/Stop system at the desirable pressure

Interstage pressure control with pressure sensors in all stages (available only for Typhoon Silent and Cyclone Silent models)

High temperature alarm & shutdown error

Oil pump lubrication (Optional)

Low Oil level sensor alarm & shutdown error

Hourmeter

Motor thermal overload protection

Voltage failure and Phase Rotation Safety device

Interstage and Final Stage Manometers

Built-In Vibration Pads

Non return valve before the outlet

Automatic belt tensioning system

Soundproof insulation (available only for Typhoon Silent and Cyclone Silent models)