GAS COMPRESSORS

“Tailor-made solutions for each individual Gas installation”

High-pressure piston GAS compressors, suitable for Nitrogen (N2), Helium (He) & Argon (Ar) applications; Compact or Silent, 3&4-staged, air cooled, oil lubricated, with Zero Loss drain system.

w

Mistral Gas

TECHNICAL DATA

Model Power Max. Pressure FAD Dimensions cm Weight
bar m³/h lit/min L W H Kg
Mistral M6-ET Classic 2.2kW/400-440V/50-60Hz 350 6.6 110 94 55 70 120

TECHNICAL DATA

Model Power Max. Pressure FAD Dimensions cm Weight
bar m³/h lit/min L W H Kg
Notus N10-ET Classic 4kW/400-440V/50-60Hz 350 10.2 170 110 55 68 146
w

Notus Gas

w

Typhoon Gas

TECHNICAL DATA

Model Power Max. Pressure FAD Dimensions cm Weight
bar m³/h lit/min L W H Kg
Typhoon Classic 18E 7.5kW/400-440V/50-60Hz 350 19.2 320 71 125 78 250-261

TECHNICAL DATA

Model Power Max. Pressure FAD Dimensions cm Weight
bar m³/h lit/min L W H Kg
Cyclone Silent 30E 11kW/400-440V/50-60Hz 350 30 500 81 124 178 567-582
Cyclone Silent 36E 15kW/400-440V/50-60Hz 350 36 600 81 124 178 594-603
w

Cyclone Gas

Design Specifications

 

Inlet Solenoid valve

Inlet Pressure regulator

Supply pressure safety valves

Supply Pressure Manometer

Inlet Pulsation chamber

Inlet Safety Pressure Switch

Inlet Vacuum Safety Pressure Switch

Oversized Stainless Steel Intercoolers & Aftercooler in all stages for optimum cooling

Advanced Design Cylinder Heads for optimum heat discharge

Safety Valves in all stages

Interstage and Final stage Condensate Separators

Final Gas Purification Filter, including coalescing prefilter (0.5 mg/m3 oil residual) and 2x large AC/MS cartridges

Large fan for high efficiency cooling of cylinders, intercoolers & aftercoolers, making the compressor capable for continuous operation

Secondary fan with independent electric motor for extra cooling (available only for Cyclone Silent model)

Zero Loss Automatic Condensate Drain system via condensate return piping system, back inside compressor’s crankcase

Star/Delta starter system

24V secondary voltage providing safety during routine operation

Main Switch

Emergency Stop button

LED TOUCH controller (Cyclone Silent models)

Automatic Start/Stop system at the desirable pressure

Interstage pressure control with pressure sensors in all stages (available only for Cyclone Silent models)

High temperature alarm & shutdown error

Oil pump lubrication (Optional)

Low Oil level sensor alarm & shutdown error

Hourmeter

Motor thermal overload protection

Voltage failure and Phase Rotation Safety device

Interstage and Final Stage Manometers

Built-In Vibration Pads

Non return valve before the outlet

Automatic belt tensioning system

Soundproof insulation (available only for Cyclone Silent models)